2016年11月16日星期三

Vertical sump pump parts inspection

What does the vertical blowdown pump part check need to be done? What is the inspection procedure for vertical sump pump parts?
1. Vertical sump pump mouth ring
Vertical sump pump mouth ring role is in the impeller and the pump shell to form a narrow, tortuous channel, to increase the flow resistance of the medium to achieve the purpose of reducing media leakage. The ring is also set to protect the main parts of the sump pump is not affected by the role of wear, wear in the mouth ring, you can repair or replace the new ring to restore the normal assembly gap, so economical and easy maintenance. The integrity of the mouth ring and its radial gap with the impeller asked the gap, in the demolition of the sump pump should first check. If the mouth ring has grooves or other defects or has ruptured, or gap over the required value, should replace the new mouth ring or repair the original mouth ring repair welding.
Vertical sump pump in operation, the corresponding ring and impeller impeller circumference is caused by wear while increasing the gap exceeds the specified value, because the new ring diameter should be the impeller inlet diameter to the preparation of the impeller and the ring between the ring Radial clearance requirements. In the repair process, the gap to a small point in order to improve the working efficiency of sump pumps and extend the use of time.
Vertical sump pump ring repair welding steps are as follows:
Brush the dirt on the mouth of the vertical blowdown pump.
With the mass fraction of 5% hydrochloric acid, activated again.
Into the temperature of 90 ℃, l0% mass fraction of caustic soda in the dip, and then placed in clean water, 90 ℃.
4) repair welding alloy. Preheat the mouth ring to about 100 ℃, with the appropriate welding ring welding alloy on the original ring, with the same alloy with the original alloy pre-cast into the electrode, along the circumference of the circular or longitudinal direction of a road even welding up (not repeated Re-welding). After welding, can be machined to the required standard size.
2. Vertical sump pump impeller
Replacement of the impeller of the blowdown pump Impeller that has been used may cause some damage and should be replaced. Impeller surface cracks. Impeller surface due to corrosion, erosion or cavitation to form more holes. Due to erosion caused by impeller cover and leaves thinning, affecting the mechanical strength. The impeller of the mouth ring hub more serious partial grinding phenomenon without repair value.
The above is the vertical sump pump parts inspection steps. If you need to replace the vertical sump pump parts, moving parts Shenlong sump pump parts.

Characteristics of Pipeline Sewage Pump

Pipeline sewage pump is the use of advanced technology at home and abroad to develop a successful energy-efficient sewage pump products, the pump has a non-clogging design and efficient features, hundreds of enterprises at home and abroad to adopt. The following describes the characteristics and application of pipeline sewage pump knowledge:
1, GW pipe sewage pump should be carefully checked before use fasteners loose or fall off, pipeline sewage pump in the transport, storage, installation process there is no damage to parts or components.
2, GW pipe sewage pump starts, the rotation direction from the inlet as a counter-clockwise rotation, if the pump reversal, simply wire the line in any two-phase wire can be adjusted to the location.
3, GW sewage pumps and piping should have their own pieces of support, not the role of pipeline weight on the pump.
4, GW sewage pump discharge piping such as installed check valve should be installed in the valve between the outside.
5, pipeline sewage pump for the convenience of maintenance and use of safety, in the pump inlet and outlet piping on the installation of a control valve and the pump outlet near the installation of a pressure gauge to ensure that the pump in the rated head and flow range to ensure that Pump the normal operation, improve the service life of the pump.
6, GW sewage pump pump shall not be long-term low-lift state of the pump running (under normal circumstances not less than the rated head lift 70%), it is best to control the proposed use of the lift within the pump to overload Burn the motor.
7, GW pipeline pump should not run in the cavitation conditions, in order to improve the service life of the pump, the pump is running without liquid, or easily damaged mechanical seals.
8, GW pipe drainage pump parts made of cast iron, open-air installation in the winter, should pay attention to prevent the break, the temperature is particularly low, it should be insulated.
Pipe-type sewage pump to install the pump must be tightened anchor bolts, so as not to start the vibration of the pump performance.
9, pipeline-type sewage pump When the high-temperature liquid pipeline in order to not bear the heat pump tube deformation, pump seat foot bolts should not be fixed, when the pipeline system in the thermal expansion and contraction, so that pump and pipeline Move together.
10, GW-type pipeline sewage pump inlet and outlet connection flange according to 684216-84 standard design, pipe flange should be accompanied by the same provisions.
11, pipe-type sewage pump installed after the toggle pump shaft, the impeller should be no friction sound or stuck phenomenon, otherwise the pump should be open for inspection and maintenance.
12, GW-type pipeline sewage pump should be installed before checking the water pump and motor fastening and whether the injury.
The above is the characteristics of the pipeline sewage pump, to further understand, move the pace of sewage pump area.

Submersible / mixing / non-blocking / self-priming sewage pump advantages

Sewage pump is a kind of pump and motor, and at the same time into the liquid work under the pump products, and the general horizontal pump or vertical sewage pump, compared to small footprint, easy installation and maintenance, continuous operation for a long time, The light weight of the components lasts longer than the average pump. There is no cavitation damage and irrigation water and other issues. Vibration and noise, the motor temperature is low, no pollution to the environment.
Xiaobian below for everyone to explain in detail, the advantages of the four sewage pumps!
(1) sewage pump vibration and noise, the motor temperature increase slowly, green, no pollution to the environment.
(2) continuous operation of sewage pump for a long time: submersible sewage pump and motor because the coaxial pump shaft is short, light weight rotating parts, so bear the load on the bearing is relatively small, longer life than the general sewage pump.
(3) compact, small footprint: submersible sewage pump because it is submerged into the liquid work. It can be directly installed in the sewage pool, without the construction of a special sewage pumping station used to install the sewage pump and motor, you can save a lot of land and infrastructure costs.
(4) there is no cavitation damage and irrigation water and other issues. In particular, the latter point to the operator to bring a great deal of convenience.
(5) easy installation and maintenance: a small submersible sewage pump can be free to install, large submersible sewage pumps are generally equipped with automatic coupling device can be automatically installed, installation and maintenance quite convenient.
Submersible sewage pump more and more widely used for a variety of industrial wastewater, sewage, liquid feed, construction site drainage, so more and more submersible sewage pump by the majority of enterprises attach importance to sewage pumps. Gradually walk in the front of the sewage industry.
Two: automatic mixing sewage pump advantages
(1) When the automatic mixing sewage pump operation, automatic mixing bottom sediment, completely prevent the deposition of dirt, without manual cleaning.
(2) a unique impeller design, with fiber, debris chopping and tearing function.
(3) the use of external circulation cooling system, sewage pump low water level operation, reduce the motor starting frequency, to extend the motor life.
(4) National Standard Atlas recommended products.
(5) Shanghai high-tech achievements into products.
Automatic mixing sewage pump is in the ordinary sewage pump on the basis of the use of automatic mixing device, the device with the motor shaft rotation, resulting in a strong mixing force, the sediment pool sediment into suspension, inhalation pump discharge is Significant of the advanced nature and the use of environmentally friendly products.
Three: the advantages of vertical non-clogging sewage pump
(1) safe and reliable to reduce maintenance costs: Balanced check of the rotor components and reasonable bearing arrangement effectively balance the radial and axial force of the pump to ensure that the unit can long-term stable operation, and has a small vibration , Low noise.
(2) over-current capacity: smooth large flow channel, a special anti-blocking impeller design to ensure efficient and non-blocking pump operation.
(3) double seal, double protection: double machine series configuration, the real double protection, to ensure motor safety.
LW vertical sewage pump working conditions
Flow rate: 2 ~ 1500 m 3 / h
Head range: 3 ~ 45m
Rated speed n: 970 ~ 2900r / min
Medium temperature: -15 ℃ ~ +60 ℃
Medium density: ≤1.3 × 10 3 kg / m 3
PH value of the medium: 5 ~ 9
System maximum working pressure: ≤ 0.6Mpa
GW pipeline pump; GW sewage pump
GW pipeline sewage pump is the use of advanced technology at home and abroad to develop a successful energy-efficient sewage pump, widely used in high-rise buildings, long-distance pipeline pressurized water or other media use, but also transport containing particulate fiber sewage, Water pump, filter flushing and condensing circulating pump.
Vertical sewage pump, can be mobile, can also be fixed for the construction, irrigation and drainage, enterprises and institutions in the process of sewage, pumping and discharge, in addition to the application of sewage, but also for hydrophobic pumps, pulp pumps, Irrigation and so on.
Four: self-priming sewage pump advantages
(1) sewage capacity: a special anti-blocking impeller design to ensure that the pump efficient and no clogging.
(2) energy efficient: the use of excellent hydraulic model, the efficiency of the pump than the average high 3 to 5%.
(3) self-priming performance: self-priming height of 1 m higher than the general self-priming pump, and self-priming time is shorter.
(4) mechanical seal with a new type of grinding Sassafras deputy, and long-term oil into the room to run.
(5) the overall structure of compact, small size, dry sound small, energy-saving effect is remarkable, easy maintenance, user-friendly replacement.
(6) automatic control cabinet according to the required liquefaction changes, automatic control of the pump hyperactivity and stop, without special care, the use of extremely convenient.
(7) according to user needs with the installation method: it to the installation, maintenance, great convenience, people do not have to enter the sump.
(8) The pump coupled with the outdoor motor, you do not need to build the pump house, can be installed directly with the outdoor use to save money.
Self-priming non-clogging sewage pump is suitable for chemical, petroleum, pharmaceutical, mining, paper, fiber, pulp, textile, food, power plant and municipal sewage works, public facilities sewage,

Submersible sewage pump and booster pump distinction

Submersible sewage pumps include booster pumps, but the booster pump is not necessarily a submerged sewage pump. In other words: the liquid sewage pump is a booster pump, but the booster pump is not necessarily a liquid sewage pump. So, the difference between liquid sewage pump and booster pump in the end what?
Before deciding on the subsea sewage pump and the booster pump, the definition of the submerged sewage pump and booster pump must be repeated. The so-called liquid sewage pump refers to the first irrigation, then use the words. Do not re-irrigation, and start running on it, and whether the self-priming pump under the impeller is immersed in water after the shutdown, liquid sewage pump is because there is a unique pump chamber structure can guarantee that after each stop impeller Can be immersed in the water to ensure its self-absorption; booster pump is the liquid can be piped to provide additional pressure pump collectively, does not refer to a certain type of pump, booster pump can be a pipeline pump, centrifugal Pump, sewage pump, liquid sewage pump, multi-stage pump and other types of pumps. If you want to self-priming booster pump to achieve self-absorption effect (the pump is located above the pool), you can add the pump in the bottom of the suction valve can be.
The above is the difference between liquid sewage pump and booster pump, to further understand, move step Shenglong  sewage pump model area.

Installation Steps of Sump Pump

In the eyes of the layman, the pump is much safer than other machines. In practice, however, pumps can create a number of safety incidents if they are not handled and managed properly. Sump drainage method, that is, in the excavation process, set in the pit at the end of the pit, and around the bottom or the central excavation ditch, the water flow into the catchment, and then use the sewage pump (submersible sewage pump ) Away. Then the stagnant water pump sewage pump installation steps which? Sump pump how to install?
1, the basement drainage pits drainage pump installation of the calculation, the installation of drainage pumps, control box installation, level installation, electrical piping, valve flange installation, drainage pipe installation.
2, sump drainage pump installation The set of sewage pump installation project, there is no single-stage centrifugal or impurity pump. Centrifugal pump and centrifugal impurity pump is the difference between the different media delivery. For example, water supply pipes, HVAC pipes, fire pipes are generally used in centrifugal pumps, papermaking process generally use impurity pump.
The sump shall be provided with centrifugal impurity pump, including pump installation, float level gauge installation, valve, soft joint, pressure gauge attachment installation, pipe connection, electrical piping and control box installation.
Second, the catchment sewage pump installation steps:
1, the preparatory work before installation, horn and so on.
2, the installation of the pump to determine the height of the suction pipe requires strict sealing, can not leak, water leakage.
3, the pump in place and alignment.
4, the pump level adjustment and the initial level of the search.
5, pump anchor bolt grouting and permanent horn placement.
6, pump to find the level and coupling center.

Installation and operation steps of tube sump pump

Tube sump pump how to install? What is the operating procedure of the sewage pump? Today, Shenlong APK sewage pump Xiaobian to introduce the installation and operation of tube sewage pump steps:
1. tube sewage pump installation
tube pump installation should meet the following requirements:
1) with the installation of sewage pump pipe foundation, the installation of pipe sewage pump should be flat so that the flange plane perpendicular to the ground.
2) installation of piping, inlet and outlet pipes should have their own frame, not as a pump pipe support, so as to avoid excessive pressure to break the flange.
3) in outdoor use, should be located in the tube sewage pump on the rain cover.
4) The pump outlet should be installed pressure gauge and gate valve, the import should be used depending on the circumstances.
5) tube sewage pump installation height, pipe length, diameter, flow rate should be consistent with the calculation results, long-distance transport should take a larger diameter to reduce losses.
6) When using, if the inlet of the sewage pump of the tube has bigger indenter, the pressure capacity of the pump body should be considered. If necessary, the pump with bigger pressure bearing capacity can be used.
2. tube sewage pump operation steps
tube sewage pump operation can be carried out according to the following steps:
1) irrigation tube sewage pump (set to self-irrigation can be free of irrigation pump), while rotating open the valve, the tube sewage pump, especially the mechanical seal cavity of the air excluded, so as to avoid mechanical seal water loss and burn.
2) Close the gate valve on the discharge line.
3) Jog the motor to check whether the direction of rotation is correct and whether the rotation of the pump is flexible.
4) Turn on the power to start the motor, when the pump reaches the normal speed, gradually open the drain valve on the tube and adjust to the required conditions. It should be noted that, in the discharge valve closed on the case, the continuous operation of the pump should not be more than 3min in order to avoid water temperature rise caused by damage to pump parts.

how to do about submersible sump pump motor water?

Submersible sump pump motor system is the power system of the entire device for the operation of submersible sump pump to provide power support, while the working environment of submersible sump pump in the liquid below, compared to the traditional pump, the working environment is more special, On its motor system waterproof performance put forward higher requirements. Once the motor system water, there will be short-circuit unit, or even cause the entire motor burned, affecting the normal fluid transport work, so to strengthen the submersible sump pump motor water fault processing is essential.
Structure Analysis of Motor Seal and Protection Device for Submersible sump Pump
The function of the submersible sump pump sealing system is to maintain the sealing performance of the whole submersible sump pump and protect the motor unit of the submersible sump pump from erosion and destruction of the debris and water. Its main structure is cable sealing, component sealing and bearing sealing, sealing The device has a good mechanical strength, the corrosion of the material has a good resistance, so as to provide a key component of the protective effect. Submersible sump pump with automatic protection device to avoid submersible sump pump at high temperatures for a long time to run. When the operating temperature exceeds the set temperature for a certain period of time, the temperature control overheating protection device will control the motor device to stop running until the winding temperature decreases, and then start the operation. At the same time the probe submersible sump pump has two protection motor, two motors directly connected to the control center of the control cabinet, when the submersible sump pump seal water leakage phenomenon, the water intrusion into the oil chamber closed system, the oil Cavity resistance rapidly decreased, then the submersible sump pump motor leakage protection system will issue an alarm, and automatically remove the submersible sump pump running power, waiting for the next step maintenance and maintenance. Submersible sump pump motor water setting is essential, submersible sump pump can detect the seal of the motor to assess whether the infiltration of water. When the water into the bearing next to the cavity inside the mechanical seal failure will directly lead to floating float position, which touches next to the float switch, and cut off the sump pump running electric device, issued the corresponding alarm signal.
Cause Analysis of Water Intake Failure of Submersible sump Pump
As the submersible sump pump in the water work, a long time running will lead to the submersible sump pump motor seal system failure, resulting in motor water failure occurred. The following detailed analysis of submersible sump pump motor water failure causes:
2.1 cable breakage
Cable damage is the main cause of motor water failure, due to the installation of submersible sump pump steel cages of the way, the installation is complete, the distance between the submersible sump pump and the covers have a longer distance, in order to provide the sump pump Electric power and power, you need to use cable underwater installation, submersible sump pump cable fixed to the chain hanging down to the bottom of the submersible sump pump, the chain with a flange hook to be fixed, but this fixed way will lead to chains Of the tension is difficult to control, while the quality of heavy cable, when the submersible sump pump running, the cables and chains will be friction, resulting in damage to the cable insulation, water will enter the submersible pump through the cable pump motor , Serious will cause the submerged sump pump burned.
2.2 integrated protection cabinet improper protection
Submersible sump pump is divided into different structures, in the upper part of the submersible sump pump is the wiring room, wiring room at the bottom of the groove is set up a water tank, while installing a floating switch, when the water into the wiring room, it will Directly back to the stagnant tank, the tank height of the water will rise to trigger a floating alarm switch, the motor water alarm signal, which plays a protective role for the motor. But some of the submersible sump pump wiring room float switch height is set properly, the height of water is not enough to inspire the alarm device, but the water will cause the entire electrical system short circuit, or even burn.
2.3 submersible sump pump seal damage
Submersible sump pump for a long time in the water, while its transport medium is more complex, which increases the probability of damage to its sealing device, when the suspended matter in the water medium more, or its corrosive strong, long Time to run will cause serious damage to the pump seal layer, causing leaking phenomenon. Moreover, more sediment in the water, the submersible sump pump impeller fouling serious, the motor bearing load increases, the bearing and box outside the skeleton oil seal between the friction increases, resulting in the phenomenon of water intrusion. In addition, submersible sump pump seal installation is not correct or improper installation of the selection will result in reduced seal life of the seal to accelerate its damage.
3 submersible sump pump motor failure water treatment
Submersible sump pump motor water will cause the operation of submersible sump pump failure, if the submersible sump pump internal water supply alarm system failure, it will lead to submersible sump pump motor burned, the following detailed analysis of submersible sump pump motor water failure Approach:
3.1 improve the submersible sump pump cable fixation
Submersible sump pump fixed way often used iron chain bundled way, but this fixed way affects the life of the cable and the use of stability, thus reducing the wear and tear of the cable insulation is essential. The current cable fixed through the use of pipe mode, the use of galvanized pipe as a cable laying, for example, a submersible sump pump cable set, the use of cable clamp fixed method, according to the use of submersible sump pump on-site conditions, to produce a can open and close Of the cable fixture, and welding the corresponding fixture fixed mold, the cable directly through the galvanized pipe fixture into the submersible sump pump, the fixed mode to improve the stability of the cable, while its simple structure, possession of the Space is small, to improve the protection of the cable, reducing the degree of wear and tear of the cable.
3.2 submersible sump pump seal inspection and replacement
Submersible sump pump seal is the key to avoid motor water, so to strengthen the submersible sump pump sealing inspection, the use of submersible sump pump will cause a long time to reduce the elasticity of the phenomenon, to strengthen the quality of sealing ring inspection, timely Replace the seals with quality problems. Especially in the work environment is more harsh water quality, to strengthen the mechanical seal components of the inspection frequency, for the occurrence of more frequent water alarm key parts, to focus on the sealing inspection. When the sealing coil of the submersible sump pump wears out, it can be exchanged directly. If the elastic spring of the fastening spring is reduced, it should be replaced with the same type of spring and fixed with wire. Moreover, in the replacement of sealing applications, should be used asbestos rope twine, and compacting its bolt fixed to improve the seal sealing performance, to avoid motor water failure.
3.3 timely replacement of submersible sump pump leakage protection components
When the submersible sump pump failure occurs when the motor water, it is necessary to cut off the motor power, to avoid further damage to the submersible sump pump, timely replacement of submersible sump pump leakage protection components to improve the detection of leakage signal accuracy. Float switch sensitivity is not high likely to cause serious water leakage tank wiring compartment, while susceptible to oily substance stuck, loss of detection, it is necessary to use a more simple structure, the higher the sensitivity of the water leakage probe, the leak detection probe has a higher detection sensitivity , Even if the trace of water into, you can also send an alarm signal in time, and cut off the power to avoid submersible sump pump by greater structural damage.
3.4 to strengthen the handling of the transport medium
The transport medium will be submersible sump pump sealing device caused some damage, while different transport medium damage to the submersible sump pump is different from more or more corrosive suspension of the transport medium is likely to cause submersible sump pump motor seal device Damage, so the poor water quality should be properly treated, the correct choice of the type of submersible sump pump to ensure that the motor shaft and the external oil seal installed correctly, to avoid the loss of elasticity of the motor seal leakage caused by the motor. To add the appropriate detergents, regularly clean up the water body of the dirt, and strengthen the monitoring of water quality and maintenance of submersible sump pump work to improve the submersible sump pump motor protection system against water effects.
4 Summary
In short, the submersible sump pump in a wide range of applications within the industry, but the submersible sump pump working environment in the water, and its commitment to the workload of large, long hours of work will cause its load overload, resulting in submersible sump pump motor Water failure, affecting its normal operation. Therefore, it is necessary to strengthen the submersible sump pump failure treatment, to improve the cable fixation, regular inspection and replacement of seal protection, and enhance the accuracy of water testing, while regular maintenance and inspection to improve the life of submersible sump pump life , To ensure the normal production work order. [Hundreds of manufacturers recommend the quality of the motor power of the Shenlong Submersible sump pump]

submersible sewage pump working principle

Submersible sewage pump is a combination of pump and motor can sneak into the work of the pump products, submersible sewage pump compact structure, covers an area of ​​small, mobile is also more convenient, because the submersible sewage pump will not cause sewage problems, So the installation of maintenance and general than the pump, but also more convenient. Today, the submersible sewage pump Xiaobian to introduce the working principle of submersible sewage pump.
Submersible sewage pump working principle: Submersible sewage pump sealed oil chamber has a high-precision anti-jamming leak detection sensors, and stator windings embedded in the thermal components, the submersible sewage pump motor absolute protection. According to user needs with automatic safety control cabinet, the submersible sewage pump leakage, leakage, overload and over-temperature and other factors that affect the safety of absolute protection, improve the safety and reliability of submersible sewage pump. Float switch can be based on the required water level changes, automatic control of the sewage pump start and stop, without special care, the use of extremely convenient. Submersible sewage pump in the structure and performance of self-priming submersible sewage pump, drawing on the advantages of similar products at home and abroad, and many users to absorb the use of the requirements and provide improved advice, developed from the set of self-absorption and sewage in one , Can be as general as the self-priming pump water without the end of the valve, without lead irrigation, but also with large pieces of solid pumping block, long fiber dirt, sediment, waste ore impurities, feces and all sewage treatment works And colloidal liquid.
Understand the working principle of submersible sewage pump, we have further understanding of the submersible sewage pump, and in the course of the operation should pay attention to the following aspects: the voltage exceeds or below the rated voltage of 10 percent, can not start the pump ; Pay attention to check the rotor running direction, from the top down to see the words should be counter-clockwise.
Above is the working principle of submersible sewage pump, we will not only operate the submersible sewage pump but also "know it, know why" to understand the working principle of submersible sewage pump. So that we can in the use of the process, to play the maximum efficiency of submersible sewage pump

how to install submersible sewage pump ball valve?

Submersible sewage pump The reason why the installation of float valve is because it can be automatically controlled
The principle of the float level controller is as follows: the liquid has buoyancy, while the float system (usually have the appropriate auxiliary equipment) is based on the buoyancy of the liquid and supporting the production, when the liquid level rise, the float system also rose, Similarly, when the liquid level drops, the corresponding drop, when up or down to the set position, the float system will touch the set position of the trip switch (or other microelectronic devices), so that the trip switch to send electrical signals , And electrical control equipment in the received signal will immediately move, cut off or power, the formation of automatic control system.
Submersible sewage pump Float valve installation is relatively complex, it is recommended that the user reference manual for submersible sewage pump to try to install, or sewage pump manufacturers in the past to help install and train personnel how to operate. The following figure in order to illustrate the installation of submersible sewage pump ball valve steps:
Heavy hammer device method:
1, the float switch cable from the center of the heavy hammer into the hole after the hole, gently push the hammer to make embedded in the hole above the plastic ring for the cable head of the thrust and fall off. (If necessary, you can use a screwdriver to remove the plastic ring). And then the shedding of the plastic ring sets in the cable you want to set a fixed weight to set the liquid hammer position.
2, gently push the hammer pull out the cable until the center of heavy hammer buckle plastic ring, heavy hammer as long as the light buckle in the plastic ring that will not fall, the plastic ring if damaged or missing, available with bare copper wire diameter Snap in the cable instead.
Precautions:
1, heavy hammer is required to attach the accessories.
2, please pull the cable directly to the control box, try to avoid the use of intermediate joints. Do not immerse the cable connector in the liquid if it is necessary to do so.
3, unused wires must be absolutely insulated.
If you have any problems during the installation, please call 400-0588-956, Zhengzhou shenlong professional engineers will guide you to one-on-one to complete the installation of submersible sewage pump float valve.

Submersible sewage pump mechanical seal

(1) a variety of submersible sewage pump mechanical seal equipment before the operation to carefully check the number of mechanical seal parts is not in line with the needs of the components for damage, especially dynamic and static ring without bumps, cracks, deformation and other defects. If in doubt, correct or replace the parts.
(2) check the sleeve or gland chamfering is not appropriate, does not meet the need to repair.
(3) submersible sewage pump mechanical seal equipment before running, it is necessary to clean and clean the mechanical seal components and their related equipment contact surface. Equipment process should adhere to the clean, especially the dynamic and static ring surface and its auxiliary sealing components should be no impurities, dust. Static, static ring surface coated with a layer of clean mechanical oil or turbine oil.
(4) In order to prevent gland face deflection, coupling correction, the submersible sewage pump pump mechanical seal tight gland bolts should be uniform, with the feeler to check the points, the fault is not greater than 0.05mm.
(5) with a feeler gauge gland and shaft or sleeve diameter of the collaborative space (ie concentricity), adjacent to uniform, the suffering of the permissible fault is not greater than 0.l0mm.
(6) the amount of spring tightening should be consistent with the rules, does not allow too much or too small appearance, to allow fault ± 2,00mm. When the tightening amount is too large, the end face increases in specific pressure, and accelerates the end face wear; when it is too small, the specific pressure is scarce and the sealing effect can not be achieved. Spring loaded into the spring seat after the move should be active. Equipment single spring, should pay attention to the rotation of the spring, the rotation should be in the opposite direction with the axis of change.
(7) equipment ring, it should be able to ensure that mobile, dynamic ring pressure to the spring should be able to automatically bounce back.
(8) When the equipment is stationary, first install the sealing ring on the back of the static ring and then in the mechanical seal. The perpendicularity of the static ring end face and the center line of the end cover should meet the technical requirements. Should be aligned anti-pin, but can not touch. Do not damage the ring end face during the installation.
(9) equipment, the process will not be allowed to hit something with the sealing element to prevent damage to the sealing element.

Professional septic tank cutting sump pump

Septic tank sump pump election Which sump pump? What kind of sump pump pumping manure better results? This is the farm users more concerned about the issue. Today, Zhengzhou shenlong pump sump pump Xiaobian to introduce a septic tank sump pump --- Shenlong cutting sump pump.
Because septic tanks are usually all kinds of livestock farms inside the stool urine, or domestic sump contains a lot of stool, confetti, suspended solids, etc. Therefore, the ordinary type of submersible sump pump can not meet the septic tank In the sump discharge problem, even if barely able to discharge, not a month, because of congestion and other problems caused by the phenomenon of submerged sump pump machine burned.
At this time, the septic tank should be selected cutting sump capacity particularly strong cutting sump pump [According to the number of fecal dirt size of the sump pump of different sizes, usually considering the diameter of 60 or more cutting sump pump]. The septic tank sump pump has a particularly strong ability to sump, animal farms can be excreted in the excrement excrete evenly, the septic tank pump can run at full head.
Because the septic tank usually contains a large number of biogas, so in the cutting sump pump operation need to pay attention to the following:
(1) sump pump before use, to check whether the sump pump cable is damaged, if damaged, be sure to replace the new national standard cable.
(2) recognize the ground wire (ground wire is generally yellow, green color or grounding symbol), in accordance with the provisions of procedures to take the ground. Use suitable protectors (such as leakage protection, air switch, phase-out overcurrent protector, etc.) Do not use a knife switch directly connected.
(3) install the water connector and the water hose (or iron pipe), put a good rope in the pump handle (cable must not replace the role of hanging rope), the pump into the pumping liquid in this, connected Power, you can use.
(4) In order to ensure personal safety, in the septic tank pump connected to work, is strictly prohibited in the vicinity of the pump installation operations (such as mobile or inspection, troubleshooting, etc.) in case of electric pump pump leakage accident!
(5) is strictly prohibited septic tank submerged sump pump the overall long-term exposure (or short-term operation) pump open and stop should not be too frequent to prevent motor overheating loss
(6) long-term pumping high sand content of the liquid septic tank sump pump over-current components wear larger, we recommend the use of automatic mixing sump pump factory, with the use of stool better results.

The maximum submersible sewage pump is 52 tons

In recent years, the process of urbanization in China has accelerated, but in the rainstorm season, the problem of urban flood control and drainage has been highlighted. Said the sewer is a city's conscience, London in this area is definitely in the forefront of the world. The sewer works from more than 100 years ago has reached a certain scale, today, it is also constantly building and improving. Drainage works can not be separated from a wide range of submersible pumps and sewage pumps, small series from the Internet to collect some of the London Lee Tunnel project information and drainage pumps to enjoy you.
[Recommended: Henan, Hubei, and many other provinces widely used in the municipal Shanghai Weihu sewage pump
The Thames Water Lee Tunnel is part of the Thames Waterway Improvement Program in London. The Thames River London Tide Improvement Program is the UK's most expensive water conservancy project. At the end of the project, the total length of the pipeline will be 39 km, with approximately 40 shafts. The pipeline, built along the River Thames, is located 25 to 80 meters below it and will be one of the deepest pipes in London and one of the deepest sewers in Europe.
The tunnel will be built at the end of the tunnel, which is nearly 6.9 kilometers long. It is the first stage of the huge construction project. The purpose of the project is to prevent rainstorms and sewage from entering the Thames during the rainstorm season. The shaft diameter of the tunnel is as high as 7.2 meters and can withstand and temporarily store about 3500,000 cubic meters of rainwater.
KSB offers a total of six pumping units for the Lee Tunnel Project in London and is installed at shafts 85 meters below the Beckton Sewage Treatment Plant in London, Britain's largest sewage treatment plant, for storm water and sewage.
This includes two slightly smaller drain pumps and four 52 tons of sewage pumps. These pumps are KSB GIW's largest and the world's largest sewage pump. Each sewage pump by the 6600V, 3.4MW motor frequency drive, impeller diameter of 2.2 meters. The project requires high wear resistance of the sewage pump, the use of white cast iron material. In order to prevent the motor temperature is too high, pump manufacturers are also equipped with special heat exchanger for the underground works. These heat exchangers can significantly reduce the energy required to dissipate heat compared to an equivalent air-cooling system.

Submersible sewage pump model

Sewage pump because of its powerful performance is widely used in various industries. At the same time, with the diversification of sewage demand, sewage pump research institutions and sewage pump manufacturer, their quality, research and development of different types of sewage pumps. So far, the more commonly used sewage pump has self-priming sewage pump, submersible sewage pump, non-clogging sewage pump, liquid sewage pump, pipeline sewage pump, septic tank sewage pump and sewage pump.
Sewage pump common model series are: WQ (QW) non-clogging submersible sewage pump, JYWQ automatic mixing sewage pump, ZW self-priming sewage pump, WL vertical non-clogging sewage pump, GW pipeline sewage pump, Sewage pump, WQJ submersible pump, WQK E paragraph black cutting sewage pump, WQP stainless steel sewage pump, WQB explosion-proof submersible sewage pump.
Parts used in the sewage pump, sewage pump impeller, pressurized water chamber, sewage pump is the two core elements. Therefore, sewage treatment pump anti-clogging performance, efficiency and cavitation performance, mainly by the pump and pressure chamber two parts to ensure.
Sewage pumps are used in a wide range of applications, mainly for:
① Enterprise unit wastewater discharge.
② urban sewage treatment plant emissions system.
③ subway, basement, air defense system drainage station.
④ hospitals, hotels, high-rise building sewage discharge.
⑤ residential sewage drainage station.
⑥ municipal engineering, construction sites in the dilute slurry emissions.
⑦ water supply plant water supply device.
⑧ farm sewage and rural farmland irrigation.
⑨ exploration of mine and water treatment equipment.
⑩ instead of shoulder to pick people Tam, suction river mud.
Want to know more about sewage pump knowledge, move step by step Wei sewage pump Encyclopedia.

Importance of submersible sewage pump flow

In general, the use of sewage submersible sewage pump beyond the scope of use will make the submersible sewage pump overload, for different submersible sewage pump, the flow of the size requirements are different, that the following specific to you, the flow of the size of the sewage submersible What are the effects of the pump?
For centrifugal submersible pumps or mixed-flow submersible pumps, the flow of excessive sewage pump will increase the shaft power, but also make the submersible sewage pump overload situation. For submersible pumps of axial-flow submersible axial-flow pumps, the flow rate is too small to increase the shaft power of the submersible sewage pump, resulting in the overload of the submersible sewage pump. Faced with this situation, we should take the following approach.
Appropriate adjustment of the valve, the centrifugal submersible pump or mixed-flow submersible pump should reduce the flow of axial flow submersible pump should increase the flow of submersible pump flow in the normal use of the scope of the avoidance of axial Type submersible pump should be increased in the course of the phenomenon of overload.
Focus on the impact of the flow size on the performance of the submersible sewage pump, and through the above simple method to improve, not only can make the submersible pump to maximize the role of pump, but also play a maintenance role. Therefore, we in the course of daily use must pay attention to changes in sewage pump flow.

Selection of Inlet and Outlet Water Pipes for Large Sewage Pump Stations

Sewage pumps in the industrial and agricultural production and life plays a huge role, precisely because of the existence of sewage pumps, our production and living environment was able to clean and tidy.
In general, the company's sewage needs of several or dozens of units to meet the needs of the family's sewage needs 1 or a few units to meet, but the city's municipal wastewater treatment needs on the need for various types of large-scale sewage pump Of the sewage pumping station can be resolved. Manufacturers recommend: sewage pumping station dedicated submersible sewage pump
The main goal of the sewage pumping station is to treat municipal wastewater discharges. According to their different uses can be divided into many types, such as water industry, water allocation industry, sewage transportation industry, with the progress of society and the continuous development of water conservancy, sewage pumping station composed of more and more, more and more functions Complete, more advanced equipment. Here is to improve the water environment, the urban sewage, industrial wastewater, the initial concentration of rainwater treatment, and relay transmission of several new modern large-scale pumping station group. We combine a city sewage treatment phase II large-scale sewage pumping station, sewage pumping station to introduce the choice of water and sewage pipeline layout.
1. Sewage pump station inlet pipe selection
Each pump station has two 2700 mm diameter pipes or 3000mmX3000mm ranging from the box culvert, the main pipeline and pumping station connected to the pool.
2. Sewage pumping station outlet pipe selection
The outlet pipe is generally also used two-way box-culvert structure, the pumping station of the water wells and the main pipe connected to each culvert diameter of 2700mm × 2700mm ~ 3300mm × 3300mm ranging from the use of cast-in-place reinforced concrete composition.

2016年11月11日星期五

Sewage pump price list

Zhengzhou Shenlong APK. has decades of experience in the production of sewage pumps, over the years, low-cost high-quality sewage pumps among the best sales, sewage pump products are more than 20 countries at home and abroad by the procurement. Now the price of Zhengzhou Shenlong sewage pump is as follows, for customers to purchase sewage pump when the reference. (Note: As the price of sewage pumps there is a certain degree of change, the specific price to the sales manager offer)
Sewage pump model
sewage pump prices(start)
S-type stainless steel sewage pump
1645¥
WQX H black engineering sewage pump
1546¥
WQX D paragraph blue suction sewage pump
998¥
WQK E black cutting sewage pump from
625¥
WQP series of stainless steel submersible sewage pump
2542¥
WQS C blue water-filled sewage pump
1460¥
WQ-JY F automatically stir the sewage pump
788¥
WQG black mine engineering sewage pump
1001¥
WQD / WQ I full stainless steel sewage pump
1000¥
WQD J stainless steel barrel sewage pump
100¥
Zhengzhou Shenlong pump in decades of development, the formation of a dedicated, innovative, self-improvement, hard work of the pump culture, and continuously expand the sewage pump product models, improve sewage pump pump production efficiency and reduce sewage pump product prices, high-quality low The price of sewage pump universal to the rest of the world! As a sewage pump brand manufacturers, we warmly welcome the arrival of customers at home and abroad! Learn more, step by step Shenlong submersible sewage pump product area.

No clogging sewage pump price?

Domestic non-clogging sewage pump relatively late start, is the introduction of foreign advanced technology on the premise, combined with the use of demand from China developed. After years of technical improvement, now with the internationally renowned non-clogging sewage pump is almost the same.
No plugging Sewage pump is widely used in the production and life of industry and agriculture, the extraction of sewage sludge in construction, sewage, feces has a strong role.
No plugging sewage pump is a big category, according to flow, head, power, etc. can be divided into many different models. Dragon is no plugging sewage pump, the Dragon no clogging sewage pump a total of 23 different models and parameters, each model of non-clogging sewage pump price is not the same. Foreign non-clogging sewage pump relative to the domestic price is slightly expensive, domestic manufacturers of non-blocking sewage pump prices also exist a certain degree of difference.
According to the survey, non-clogging sewage pump prices are as follows:
             
Brand
Price
xuefulong
300-1450
Yuelang
380-3050
Taipingyang
1100-1120
Changyuan
750
ShanghaiSubmersible
505-1830
Guangquan
259-2390
Xiongmao
1950
Huatinghu
4800
Lianquan
4450-5080
shenlong is no clogging sewage pump compared with foreign brands, the price is lower, compared to the same price of domestic non-clogging sewage pump quality is better. Learn more, step by step shenlong no-blocking sewage pump area.